Fieldpiece Advanced HVAC Kit
Fieldpiece 10 CFM R32 Two Stage Vacuum Pump VPX7INT
Fieldpiece Digital Refrigerant Recovery Machine MR45INT
Fieldpiece 4-Valve Wireless Refrigerant Manifold SM480vINT
Fieldpiece Infrared Refrigerant Leak Detector DR82
Fieldpiece Job Link Charge & Air Test Wireless Probe Kit JL3KH6
Fieldpiece Job Link Wireless Manometer Kit JL3KM2
Fieldpiece Digital Wireless Vacuum Gauge MG44
Fieldpiece Wireless Electronic Refrigerant Scale 114KG - SR47
Fieldpiece True RMS AC/DC Wireless Power Clamp Meter - SC680INT
  • SKU: AdvancedHVACPack

Fieldpiece Advanced HVAC Kit

$8,615.08 $9,068.51
GST included.
    DESCRIPTION

    This Cool Tools HVAC-R exclusive Advanced HVAC Kit for air conditioning and refrigeration includes:


    FEATURES AND CAPABILITIES

    Fieldpiece VPX7 283 L/M 10 CFM A2L Certified 2 Stage Vacuum Pump - VPX7INT

    The NEW Fieldpiece VPX7INT high-efficiency Vacuum Pump with RunQuick™ Oil Change System - No Fuss - No Mess


    • 10 CFM (283 l/m)flow rate with 15 microns ultimate vacuum
    • 3/4 HP DC motor
    • RunQuick™ Oil Change System offers on-the-fly oil changes in seconds
    • Extra oil bottle storage
    • Includes 2 x 237ml Oil filled RunQuick Oil Cartridges
    • Backlit oil reservoir to view condition of oil and system
    • Water resistant to withstand direct rain
    • Patented lightest weight pump
    • Port Sizes: (1) 1/4”, (2) 3/8”, (1) 1/2” for easy hose connections
    • Sturdy base stays upright
    • Small footprint – 1,346 cubic inches
    • Quarter-turn gas ballast with LED indicator
    • Convenient, removable cord storage
    • Error messages: indicate wrong power source or other errors
    • Suitable for A2L class refrigerants
      • R32, R1234YF, R1234ZE, R512A, 419B, 439A & other 

    WHAT'S INCLUDED

    • VPX7INT Vacuum Pump
    • 2 x 8oz RunQuick Oil Containers (Filled)
    • Operator’s Manual

    SPECIFICATIONS

    Flow Rate 10 CFM (283 l/m)
    Oil Capacity 8oz (237mL)
    Oil Compatibility Fieldpiece Vacuum Pump Oil (Highly refined and optimized for proper sealing and lubrication)
    Fieldpiece part numbers OIL8X3, OIL32, OIL128
    Oil Backlight Blue LED
    Oil Drain Ball valve
    Port Sizes (1) 1/4”, (2) 3/8”, (1) 1/2”
    Compressor Rotary vane, two stage
    Motor  3/4 HP Brushless DC
    RPM 2500
    Power Source 240 VAC @ 50 Hz 1 phase
    Nominal Current Draw 6.0 AAC
    Ultimate Vacuum at Input Ports 15 microns
    Operating Environment -1.1°C to 50°C
    Dimensions 201 mm x 296 mm x 406 mm
    Weight 11.1 kg


    Fieldpiece Recovery Unit - MR45INT

    Refrigerant Recycling has never been easier or faster with the MR45INT Recovery Machine

    • Dual cylinder compressor with long life and low friction with ceramic lined cylinders

    • Auto Shut Off when -10 Kpa reached
    • Protected from voltage drop (runs as low as 190 VAC)
    • Single dial self purge
    • Twice the RPMs (3,000) and twice the horsepower (1HP - 0.745kW) with DC Motor
    • Extra large condenser cools faster, especially on hot days
    • Light Weight at only 10 Kgs
    • Water & Rain resistant
    • Easy access ports
    • Easy hose connections and built-in power cord storage                          
    • Large backlit display with status messages
    • UL Verified to Section 608 of EPA Clean Air Act
    • UL Verified to AHRI Standard 740
    • A2L ready including R32
    • Also can be used for transferring SF6 (sulfur hexafluoride) a non-flammable gas used in electrical components.

    WHAT'S INCLUDED

    • MR45 Refrigerant Recovery Machine
    • 10 Extra Mesh Screens for Input Port
    • 3 Extra O-ring for Input Port
    • Operator’s Manual

    SPECIFICATIONS

    Display 2 x 10000 count LCD with status messages
    Backlight Blue color
    Measurement rate 3.3 times per second, nominal
    Input Port Pressure Sensor Range -30” Hg to 600 psig
    Output Port Pressure Sensor Range -30” Hg to 600 psig
    High Pressure Cutoff 558 psig, nominal
    Resolution and Units 1 psig (1” Hg), 0.05 bar (2 cmHg),  0.01 Mpa (2 cmHg), 5 Kpa (2 cmHg)
    Pressure Sensor Accuracy ± 0.5 “ Hg (Vacuum)  ± (0.6% of reading +2 psig)
    Final Recovery Vacuum  14.9” Hg
    Compressor Twin cylinder reciprocating (oil-less)
    DC Motor 1 HP (variable smart speed)
    Power Source 220 - 240 VAC @ 50 Hz 1 phase
    Max Current Draw 7.0 Amp
    Valve Single dual-route ball valve
    Input Port Filtration 9 mm mesh screen, stainless
    Dimensions 376 mm x 250 mm x 344 mm
    Weight 10 Kgs
    Operating Environment 32°F to 122°F (0°C to 50°C)
    Storage Environment -4°F to 140°F (-20°C to 60°C)
    Approved Refrigerants R12, R12345YF, R134A, R22, R32, R401A (MP39), R401B, R401C, R402A, R402B, R404A, R407A, R407B, R407C, R407D, R408A, R409A, R410A, R412A, R500, R502, R507, R509

     

    Fieldpiece Wireless 4-Valve Digital Manifold with Micron Gauge - SM480vINT

    The newly designed Fieldpiece Manifolds are stronger and more robust than ever before!

        Data Logging
        • Stores up to 9 jobs internally
        • Easy download via USB port
        • Displays % free storage space before logging begins
        • Logs up to 7 days (168 continuous hours)

        Tightness Test built-in feature
        • Check for leaks after repairs or installations
        • View pressure differential over time
        • Timer tracks duration of test
        • Temperature compensated with SL temp to avoid false positives

        Customisable Menu
        • Adjust auto power off duration
        • Adjust backlight duration
        • Set high and low vacuum alarms
        • Select each unit of measurement individually

        Receives Wireless Measurements
        Add Job Link Tools to your arsenal and get live readings directly on the SMAN manifold screen from the Job Link Psychrometers (JL3RH), Job Link Pipe Clamps (JL3PC), and SRS3 Refrigerant Scale.
        Place pipe clamps in the perfect location. Monitor and record live refrigerant usage for precise recovery, charging, and documentation. View live air measurements and calculations while making adjustments.

        Increase Professionalism with Job Link® System App
        Streamline and simplify your call even further with the Job Link System App. See your measurements up to 100 metres away on your mobile device. Document your work and provide professional reports, including refrigerant weight usage, by simply connecting to the Job Link System app. Helps to reduce call-backs and increase profits.
        • View measurements on SMAN and/or in Job Link App
        • Monitor and record refrigerant weight
        • Direct 100 meter wireless range (no transmitter needed)

        WHAT'S INCLUDED

        • SM480vINT
        • 2 x TC24 Wired Type-K Pipe Clamp thermocouple
        • 1 x ATA1 Type-K Bead Thermocouple with clip
        • 1 x ANC11 Padded Drawstring Case

        SPECIFICATIONS

        Display LCD (5 inches diagonal)
        Backlight Blue (adjustable duration)
        Low Battery Indication Displayed when the battery voltage drops below the operating level
        Over Range Display OL for pressure, – – – – for temperature
        Auto Power Off 30 minutes of inactivity (adjustable)
        Maximum Manifold Pressure 800 Psig (5500 kPa)
        Battery Type 6 x AA alkaline
        Battery Life 350 hours typical (without vacuum, backlight, and wireless)
        Radio Frequency 2.4 GHz
        Wireless Range 305 meters line of sight – distance decreases through obstructions
        Data Port Micro USB (for extracting data logs or updating firmware)
        Operating Environment 0°C to 50°C at <75% RH
        Storage Environment -20°C to 60°C at <80% RH (with battery removed)
        Temperature Coefficient 0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°C)
        Weight 1.83 kg
        Water Resistant Designed to IP54


        Fieldpiece Infrared Refrigerant Leak Detector - DR82

        Infrared Refrigerant Leak Detector for HVACR - Superior Sensitivity in a Rugged Design for HVACR

        • 10-year sensor life
        • Doesn’t trigger on soap bubbles and oil
        • Compact – designed to fit in your hand
        • Multiple alarms
        • LED lighted tip and loud beep help find leaks in noisy and dark environments
        • Sensitivity better than 0.03 oz/yr (1g/yr)
        • Ruggedized and IP54-certified
        • 10-hour battery charge
        • Bright blue, back-lit LCD screen with clear numerical leak size indicator and bar graph
        • Non-conductive, sturdy probe that stays where you want it.
        • Weighs less than a pound
        • Works on A2L Refrigerants

        WHAT'S INCLUDED

        • Advanced IR Refrigerant Leak Detector (DR82)
        • 5 x Replacement Filtered Tips (RFT6)
        • Wall Charger with USB-C Cable (RCA3)
        • Blow-Molded Case (ABM2)
        • Operator’s Manual

        SPECIFICATIONS

        Sensor Type Infrared (IR)
        Sensor Life 10 years typical
        Sensitivity Levels High, medium, low, turbo (selectable)
        Maximum Sensitivity 0.03 oz/yr (1g/a), stationary; 0.1 oz/yr (3g/a), in motion
        Display Type LCD (backlit for indoor use)
        Detection Feedback Red tip LED, LCD bar graph, LCD digits, beeper
        Refrigerants Detects CFC, HFC, HCFC, HFO and blends and
        doesn’t trigger on oil or soap bubbles
        Response Time <1 seconds typical
        Recovery Time <5 seconds typical
        Body Type Compact, rugged overmolded
        Battery Type 3.7 VDC (nominal) 2600mAh, non-replaceable
        Charge Time 6 hours typical with included charger.
        Battery Life 10 hours typical, backlight off
        Auto Power Off 10 minutes without detection or button press
        Operating Environment 32°F to 104°F (0°C to 40°C); < 75% RH (non-condensing)
        Storage Temperature -4°F to 140°F (-20°C to 60°C); < 80% RH
        Weight 14 oz (400g)
        Water Resistance Designed to IP54

         

        Fieldpiece Job Link Charge & Air Test Bluetooth Probe Kit JL3KH6

        Take a full system snapshot quickly and easily with the JL3KH6 Charge and Air Test Kit.

        • All measurements can be sent up to 1000’ away directly to your mobile device with the Job Link® System mobile app. 
        • Each tool is designed for agility and speed.
        • The pressure probes fit into tight spaces.
        • The pipe clamps use the new Rapid Rail™ sensor design delivering accuracy, speed, and agility, even on the most awkward pipe configurations.
        • The psychrometers’ flexible narrow probes and configurable magnet make it easy to measure supply plenums, ducts, and elevated registers. Do more with Job Link probes!

        WHAT'S INCLUDED

        • 2 x JL3PR Job Link Pressure Probes for Discharge & Suction Pressure
        • 2 x JL3PC Job Link Premium Pipe Clamp Probes for liquid line subcooling & suction line Superheat
        • 2 x JK3RH Flex Job Link Psychrometer Probes for obtaining Dry Bulb, Wet Bulb, Dew Point Temperatures & Relative Humidity [ RH%]
        • Contained in a quick access padded ANC18 Protective Case
        • 2 x AAA Batteries Per Probe (8 Total)

        SPECIFICATIONS

        Wireless Range: +300 metres
        Wireless Frequency: 2.4 GHz
        Battery: 2 x AAA (included)
        Battery Life: 150 hrs typical alkaline
        Auto Power Off (APO): 2 hrs (can be disabled)
        Minimum Device Requirement: BLE 4.0 devices running iOS® 7.0 or AndroidTM 5.0

        Job Link™ Pressure Probe - JL3PR
        Connector Type: 45° Standard 1/4” NPT female flare
        Best Accuracy: ±1 psig (±7 kPa)
        Measurement Range: 0 to 580 psig (0 to 4000 kPa)
        Maximum Overload: 800 psig (5500 kPa)
        Water Resistant: Designed to IP55

        Job Link™ Premium Pipe Clamp Probe - JL3PC
        Pipe Compatibility: Electrically conductive 1/4” to 1 3/8” (6.4mm to 34.9mm) dia.
        Accuracy: ±1°F (±0.6°C)
        Measurement Range: -50°F to 257°F (-46°C to 125°C)
        Stabilization Time: 3 seconds typical
        Measurement Feedback: Beeper and LED
        Water Resistant: Designed to IP55
        Patent: Pending

        Job Link™ Flex Psychrometer Probe - JL3RH
        Flexible Probe: 0.36” (9mm) diameter, 9.25” (235mm) length
        Best Accuracy: ±1°F (±0.6°C) ±2.5 %RH
        Measurement Range: -4°F to 140°F (-20°C to 60°C) 0 %RH to 100 %RH


        Fieldpiece Job Link Wireless Manometer Kit JL3KM2

        The revolutionary new JL3KM2 Job Link® System Manometer probes give HVAC-R pros the freedom to work the way they want to — unrestricted by hoses, so technicians get readings from optimal locations on every system, every time.

        • All-in-one static, gas and draft pressure
        • Record up to 8 readings at once* in Job Link App
        • Accurate and stable measurements
        • Reliable pressure regardless of location
        • Individual pressure readouts
        • Switchable P1 – P2 indicator
        • Easy zero to atmosphere
        • Long-range wireless
        • Job Link® System app compatible

        WHAT'S INCLUDED

        • 2x JL3MN Manometer Probe
        • 2x ASP2 Static Pressure Probe and Hose
        • 2x Brass Screw Fitting with Extra Hose
        • 2x Slide Gas Adapter
        • 4x AAA Batteries
        • 1x Padded Case

        SPECIFICATIONS

        Minimum Device Requirement BLE 4.0 devices running iOS® 7.0 or Android™ 5.0 (Latest compatibility at www.fieldpiece.com)
        Compatible Media Dry, non-corrosive gas
        Pressure Port Tube connector for flexible tubing (4.5 to 8mm ID)
        Units of Measure inWC, mmWC, mbar, psi, Pa
        Accuracy and Ranges: inWC: ±0.02 on 0.00 to ±2.00 (±1.5% FS on 2.00 to ±60.00);
        mmWC: ±0.5 on 0.0 to ±51.0 (±1.5% FS on 51.0 to ±1500.0);
        mbar: ±0.05 on 0.00 to ±5.00 (±1.5% FS on 5.00 to ±150.00);
        psi: ±0.001 on 0.000 to ±0.072 (±1.5% FS on 0.072 to ±2.165);
        Pa: ±5 on 0 to 498 (±1.5% FS on 498 to ±14930)
        Maximum Overload Pressure 321.08 inWC (11.6 psi; 80.0 kPa)
        Battery Type 2 x AAA, NEDA 24A, IEC LR03
        Battery Life 150 hours typical alkaline. LED slow-blinks red when battery replacement is needed.
        Auto Power Off: 2 hours (APO can be disabled)
        Wireless Range 1000 feet (305 meters) line of sight. Obstructions affect distance.
        Radio Frequency 2.4 GHz
        Operating Environment -10°F to 122°F (-23°C to 50°C) at <75% RH
        Storage Temperature -10°F to 140°F (-23°C to 60°C) at <80% RH (with batteries removed)
        Temperature Coefficient 0.1 x (specified accuracy) per 1.8°F (-10°F to 64°F, 82°F to 122°F), per 1°C (-23°C to 18°C, 28°C to 50°C)
        Weight 0.30 lbs (137 g)


        Fieldpiece Wireless Probe Vacuum Gauge with LCD Display - MG44

        The NEW MG44 Micron Gauge Impact and Weather Resistant designed for the field

        • Confidently perform evacuations with a reliable, leak-proof seal.
        • Reversible angled coupler and new cylindrical design are easier to fit into tight spaces.
        • There are three ways to use:
          • View from up to 300 metres away (line of sight) via the Job Link® mobile app
          • View on the Fieldpiece SMAN™ Refrigerant Manifold SM380INT or SM480INT
          • View direct from the MG44’s display
        • Three ways to view the new larger backlit LCD screen is easier to read and its dot-matrix display shows more info including:
          • bar graph
          • rate
          • rate meter
        • IP54-rated weather-resistant.
        • Rugged over-molded construction for extreme impact resistance.
        • Range 50 to 25,000 microns
        • Units of measure: microns (µm) of mercury, mmHg, mbar, mTorr, Torr, and Pascals

        WHAT'S INCLUDED

        • Micron Vacuum Gauge - MG44
        • Reversible Coupler Fitting
        • Operator's Manual
        • 2 x AA Alkaline Batteries

        SPECIFICATIONS

        Minimum Device Requirement BLE 4.0 devices running: iOS® 7.0 or Android™ 5.0
        (Latest compatibility at www.fieldpiece.com)
        Connector type 1/4” SAE male fitting
        Accuracy ±(5% of reading + 5 microns) at 77°F (25°C), 50 to 1000 microns
        Range and Units 50 to 25000 microns of mercury (English),
        6 to 3333 Pascals (Metric),
        0.06 to 33.33 mBar (Metric),
        50 to 25000 mTorr (Metric),
        0.05 to 25 Torr (Metric, equivalent to mmHg)
        Best Resolution 1 micron of mercury (below 2000 microns),
        1 Pascal (below 250 Pascals),
        0.001 mBar (below 2.5 mBar),
        1 mTorr (below 2000 mTorr),
        0.001 Torr (below 2.5 Torr, equivalent to mmHg)
        Battery Type 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6
        Battery Life 40 hours typical alkaline
        Auto Power Off 15 minutes default (APO adjustable)
        Wireless Range 1000 feet (305 meters) line of sight.
        Obstructions affect distance.
        Radio Frequency 2.4 GHz
        Water Resistence IP55
        Operating Environment 14°F to 122°F (-10°C to 50°C) at <75% RH
        Storage Temperature -4°F to 140°F (-20°C to 60°C) at <80% RH (with batteries removed)
        Weight 0.66 lbs (300 g)

         


        Fieldpiece Wireless Electronic Refrigerant Scale 114KG - SR47

        The New Heavyweight Champion

        • 13″ platform to fit larger tanks and integrated bumpers for increased durability
        • Strong enough to hold a maximum load of 252 lbs
        • Wireless remote control with LED backlight – can be stored inside the scale, and makes viewing data easy
        • Industry-leading accuracy: ±0.03%rdg + 0.25 oz
        • Lightweight. Total weight of scale and remote is ~7 lbs
        • Water resistance can handle any job site
        • Connects to the Job Link® System App with 1000′ wireless range and Digital Manifolds SM480V & SM380V
        • Platform battery lasts 200+ hours – it can literally work all week if needed
        • Easy-to-use raised power button now located at base of scale
        • A2L compatible

          WHAT'S INCLUDED

          • 1 x Wireless Refrigerant Scale Platform SR47
          • 1 x Wireless remote
          • 1 x 9V Battery (remote)
          • 6 x AA Batteries (platform)
          • 1 x Carrying case
          • Operator's Manual

          Please Note: Gas bottle in the image not included, for demonstration purposes only.

          SPECIFICATIONS

          Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative humidity
          Over range “OL” is displayed
          Maximum load 252 lbs (114 kg)
          Max tank base diameter 13 inches (33 cm)
          Auto power off 30 minutes of inactivity (no change in weight or buttons pressed), (APO can be disabled)
          Backlight Blue, turns off in 2 minutes if no buttons are pressed
          Accuracy ±0.03%rdg + 0.25 oz (10 g), 0 to 66 lbs (0 to 30 kg)
          ±0.05%rdg + 0.25 oz (10 g), 66 to 252 lbs (30 to 114 kg)
          Resolution and Units lb oz (0.25 oz), lb (0.1 lb), oz (0.3 oz), kg g (10 g), kg (0.1 kg), g (10 g)
          Temperature coefficient 0.1 x (specified accuracy) per °F
          Wireless Range 1000 feet (305 meters) line of sight
          Radio Frequency 2.4 GHz
          Battery Type Remote Display: 1 x 9V, NEDA 1604, JIS 006P, IEC 6F22
          Platform: 6 x AA, NEDA 15A, JIS UM3, IEC LR6
          Battery Life Remote Display: 80 hours typical alkaline (backlight off)
          Platform: 200 hours typical alkaline
          Remote Display 80 hours typical alkaline (without backlight)
          Platform 200 hours typical alkaline
          Operating environment 32°F to 122°F (0°C to 50°C) at <75% RH
          Storage temperature -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed)
          Water resistant IP54 (Platform), IP64 (Remote)
          Weight Platform with battery ~7 lbs (3190 g)
          Remote with battery 0.49 lbs (220 g)

           

          Fieldpiece True RMS AC/DC Wireless Power Clamp Meter - SC680INT

          Built for HVAC-R - Packed with ideal measurements perfect for mini-splits!

          Whether you’re working on small circuitry in mini-splits or on large commercial units, the new SC680 is packed with everything you need to install, service or troubleshoot any HVAC-R system.

          • Measures Power (kW) for system efficiency
          • Verify 3-phase rotation with just two leads.
          • Filter out noise to get true voltage and frequency with low pass filter
          • Take more accurate VAC and AAC readings with True RMS
          • Has True RMS and Low Pass Filter (LPF) to obtain accurate VFD readings
          • Test Diodes and Resistance up to 50MΩ
          • Measures start/run capacitors
          • Magnet for mounting meter during use
          • Molex tips reach into power connectors
          • Safety rated CAT IV-600V/CAT III-1000V

          WHAT'S INCLUDED

          • SC680INT Bluetooth Clamp Meter
          • ADLS2 Deluxe Test Lead Set with Gold Plated Tips with Removable Sheath
          • ASA2 Short Leads with Alligator Clips
          • 2 x ATB1 Type K Thermocouples
          • 2 x Velcro Straps
          • 9V Alkaline Battery (not installed)
          • ANC7 Padded Case
          • Operator's Manual

          SPECIFICATIONS

          Measure up to 600 Amps AC & DC
          Display 10000 count dual display
          Backlight 5 minute duration with auto-off, blue color
          Overrange “OL” or “-OL” is displayed
          Measurement rate 3.3 times per second, nominal Zero: Automatic
          Operating environment 32°F to 122°F (0°C to 50°C) at <70%RH
          Storage temperature -4°F to 140°F (-20°C to 60°C), 0 to 80%RH (with battery removed)
          Accuracy Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH
          Temperature coefficient 0.1 x (specified accuracy) per °C [0°C to 19°C (32°F to 66°F),
          28°C to 50° C (82°F to 122°F)]
          APO (Auto Power Off) Approx. 30 minutes
          Power Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
          Battery life 100 hours typical alkaline (No wireless, no backlight)
          Low battery indication Battery icon blinks and "batt" is displayed when the battery voltage drops below the operating level
          Dimensions 247mm(H) x 79mm(W) x 48mm(D)
          Weight Approx. 345g including battery
          Altitude Up to 6562 ft (2000m)
          Overload protection 1000VDC or 750VAC rms unless otherwise stated
          Test leads Use UL listed test leads that comply to UL61010-031 rated CATIV 600V, CATIII 1000V or above. Included test leads are gold-plated and have removable safety caps.

          Please operate the instrument following all instructions of the operator's manual to avoid impairing the safety of the product.

           

          WARRANTY

          1 Year from Date of Purchase (​excludes Consumables such as Filters, Gaskets, Leads, Batteries, Fuses, Sensors, Case etc)

          AUTHORISED RETAILER

          Buy with 100% confidence knowing your purchase is backed by the full Manufacturer's Warranty. Please register your product with provided warranty card.

           

          SCROLL UP AND "ADD TO CART" TODAY.

          SHIPPING

          Australia-wide Flat Rate shipping of $15.00 per order.
          This includes multiple products up to 5kg only.

          Additional cost applies for orders over 5kg. Contact us for quotation.

          REVIEWS

          RELATED PRODUCTS



          SELLER REVIEWS


          BACK TO TOP