No Products in the Cart
1800 870 382
Call us Toll Free or Chat Now
This Cool Tools HVAC-R exclusive Advanced HVAC Kit for air conditioning and refrigeration includes:
FEATURES AND CAPABILITIES
Fieldpiece VPX7 283 L/M 10 CFM A2L Certified 2 Stage Vacuum Pump - VPX7INT
The NEW Fieldpiece VPX7INT high-efficiency Vacuum Pump with RunQuick™ Oil Change System - No Fuss - No Mess
WHAT'S INCLUDED
SPECIFICATIONS
Flow Rate | 10 CFM (283 l/m) |
Oil Capacity | 8oz (237mL) |
Oil Compatibility | Fieldpiece Vacuum Pump Oil (Highly refined and optimized for proper sealing and lubrication) |
Fieldpiece part numbers | OIL8X3, OIL32, OIL128 |
Oil Backlight | Blue LED |
Oil Drain | Ball valve |
Port Sizes | (1) 1/4”, (2) 3/8”, (1) 1/2” |
Compressor | Rotary vane, two stage |
Motor | 3/4 HP Brushless DC |
RPM | 2500 |
Power Source | 240 VAC @ 50 Hz 1 phase |
Nominal Current Draw | 6.0 AAC |
Ultimate Vacuum at Input Ports | 15 microns |
Operating Environment | -1.1°C to 50°C |
Dimensions | 201 mm x 296 mm x 406 mm |
Weight | 11.1 kg |
Fieldpiece Recovery Unit - MR45INT
Refrigerant Recycling has never been easier or faster with the MR45INT Recovery Machine
Dual cylinder compressor with long life and low friction with ceramic lined cylinders
WHAT'S INCLUDED
SPECIFICATIONS
Display | 2 x 10000 count LCD with status messages |
Backlight | Blue color |
Measurement rate | 3.3 times per second, nominal |
Input Port Pressure Sensor Range | -30” Hg to 600 psig |
Output Port Pressure Sensor Range | -30” Hg to 600 psig |
High Pressure Cutoff | 558 psig, nominal |
Resolution and Units | 1 psig (1” Hg), 0.05 bar (2 cmHg), 0.01 Mpa (2 cmHg), 5 Kpa (2 cmHg) |
Pressure Sensor Accuracy | ± 0.5 “ Hg (Vacuum) ± (0.6% of reading +2 psig) |
Final Recovery Vacuum | 14.9” Hg |
Compressor | Twin cylinder reciprocating (oil-less) |
DC Motor | 1 HP (variable smart speed) |
Power Source | 220 - 240 VAC @ 50 Hz 1 phase |
Max Current Draw | 7.0 Amp |
Valve | Single dual-route ball valve |
Input Port Filtration | 9 mm mesh screen, stainless |
Dimensions | 376 mm x 250 mm x 344 mm |
Weight | 10 Kgs |
Operating Environment | 32°F to 122°F (0°C to 50°C) |
Storage Environment | -4°F to 140°F (-20°C to 60°C) |
Approved Refrigerants | R12, R12345YF, R134A, R22, R32, R401A (MP39), R401B, R401C, R402A, R402B, R404A, R407A, R407B, R407C, R407D, R408A, R409A, R410A, R412A, R500, R502, R507, R509 |
Fieldpiece Wireless 4-Valve Digital Manifold with Micron Gauge - SM480vINT
The newly designed Fieldpiece Manifolds are stronger and more robust than ever before!
Data Logging
• Stores up to 9 jobs internally
• Easy download via USB port
• Displays % free storage space before logging begins
• Logs up to 7 days (168 continuous hours)
Tightness Test built-in feature
• Check for leaks after repairs or installations
• View pressure differential over time
• Timer tracks duration of test
• Temperature compensated with SL temp to avoid false positives
Customisable Menu
• Adjust auto power off duration
• Adjust backlight duration
• Set high and low vacuum alarms
• Select each unit of measurement individually
Receives Wireless Measurements
Add Job Link Tools to your arsenal and get live readings directly on the SMAN manifold screen from the Job Link Psychrometers (JL3RH), Job Link Pipe Clamps (JL3PC), and SRS3 Refrigerant Scale.
Place pipe clamps in the perfect location. Monitor and record live refrigerant usage for precise recovery, charging, and documentation. View live air measurements and calculations while making adjustments.
Increase Professionalism with Job Link® System App
Streamline and simplify your call even further with the Job Link System App. See your measurements up to 100 metres away on your mobile device. Document your work and provide professional reports, including refrigerant weight usage, by simply connecting to the Job Link System app. Helps to reduce call-backs and increase profits.
• View measurements on SMAN and/or in Job Link App
• Monitor and record refrigerant weight
• Direct 100 meter wireless range (no transmitter needed)
WHAT'S INCLUDED
SPECIFICATIONS
Display | LCD (5 inches diagonal) |
Backlight | Blue (adjustable duration) |
Low Battery Indication | Displayed when the battery voltage drops below the operating level |
Over Range Display | OL for pressure, – – – – for temperature |
Auto Power Off | 30 minutes of inactivity (adjustable) |
Maximum Manifold Pressure | 800 Psig (5500 kPa) |
Battery Type | 6 x AA alkaline |
Battery Life | 350 hours typical (without vacuum, backlight, and wireless) |
Radio Frequency | 2.4 GHz |
Wireless Range | 305 meters line of sight – distance decreases through obstructions |
Data Port | Micro USB (for extracting data logs or updating firmware) |
Operating Environment | 0°C to 50°C at <75% RH |
Storage Environment | -20°C to 60°C at <80% RH (with battery removed) |
Temperature Coefficient | 0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°C) |
Weight | 1.83 kg |
Water Resistant | Designed to IP54 |
Fieldpiece Infrared Refrigerant Leak Detector - DR82
Infrared Refrigerant Leak Detector for HVACR - Superior Sensitivity in a Rugged Design for HVACR
WHAT'S INCLUDED
SPECIFICATIONS
Sensor Type | Infrared (IR) |
Sensor Life | 10 years typical |
Sensitivity Levels | High, medium, low, turbo (selectable) |
Maximum Sensitivity | 0.03 oz/yr (1g/a), stationary; 0.1 oz/yr (3g/a), in motion |
Display Type | LCD (backlit for indoor use) |
Detection Feedback | Red tip LED, LCD bar graph, LCD digits, beeper |
Refrigerants | Detects CFC, HFC, HCFC, HFO and blends and doesn’t trigger on oil or soap bubbles |
Response Time | <1 seconds typical |
Recovery Time | <5 seconds typical |
Body Type | Compact, rugged overmolded |
Battery Type | 3.7 VDC (nominal) 2600mAh, non-replaceable |
Charge Time | 6 hours typical with included charger. |
Battery Life | 10 hours typical, backlight off |
Auto Power Off | 10 minutes without detection or button press |
Operating Environment | 32°F to 104°F (0°C to 40°C); < 75% RH (non-condensing) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C); < 80% RH |
Weight | 14 oz (400g) |
Water Resistance | Designed to IP54 |
Fieldpiece Job Link Charge & Air Test Bluetooth Probe Kit JL3KH6
Take a full system snapshot quickly and easily with the JL3KH6 Charge and Air Test Kit.
WHAT'S INCLUDED
SPECIFICATIONS
Wireless Range: +300 metres
Wireless Frequency: 2.4 GHz
Battery: 2 x AAA (included)
Battery Life: 150 hrs typical alkaline
Auto Power Off (APO): 2 hrs (can be disabled)
Minimum Device Requirement: BLE 4.0 devices running iOS® 7.0 or AndroidTM 5.0
Job Link™ Pressure Probe - JL3PR
Connector Type: 45° Standard 1/4” NPT female flare
Best Accuracy: ±1 psig (±7 kPa)
Measurement Range: 0 to 580 psig (0 to 4000 kPa)
Maximum Overload: 800 psig (5500 kPa)
Water Resistant: Designed to IP55
Job Link™ Premium Pipe Clamp Probe - JL3PC
Pipe Compatibility: Electrically conductive 1/4” to 1 3/8” (6.4mm to 34.9mm) dia.
Accuracy: ±1°F (±0.6°C)
Measurement Range: -50°F to 257°F (-46°C to 125°C)
Stabilization Time: 3 seconds typical
Measurement Feedback: Beeper and LED
Water Resistant: Designed to IP55
Patent: Pending
Job Link™ Flex Psychrometer Probe - JL3RH
Flexible Probe: 0.36” (9mm) diameter, 9.25” (235mm) length
Best Accuracy: ±1°F (±0.6°C) ±2.5 %RH
Measurement Range: -4°F to 140°F (-20°C to 60°C) 0 %RH to 100 %RH
Fieldpiece Job Link Wireless Manometer Kit JL3KM2
The revolutionary new JL3KM2 Job Link® System Manometer probes give HVAC-R pros the freedom to work the way they want to — unrestricted by hoses, so technicians get readings from optimal locations on every system, every time.
WHAT'S INCLUDED
SPECIFICATIONS
Minimum Device Requirement | BLE 4.0 devices running iOS® 7.0 or Android™ 5.0 (Latest compatibility at www.fieldpiece.com) |
Compatible Media | Dry, non-corrosive gas |
Pressure Port | Tube connector for flexible tubing (4.5 to 8mm ID) |
Units of Measure | inWC, mmWC, mbar, psi, Pa |
Accuracy and Ranges: | inWC: ±0.02 on 0.00 to ±2.00 (±1.5% FS on 2.00 to ±60.00); mmWC: ±0.5 on 0.0 to ±51.0 (±1.5% FS on 51.0 to ±1500.0); mbar: ±0.05 on 0.00 to ±5.00 (±1.5% FS on 5.00 to ±150.00); psi: ±0.001 on 0.000 to ±0.072 (±1.5% FS on 0.072 to ±2.165); Pa: ±5 on 0 to 498 (±1.5% FS on 498 to ±14930) |
Maximum Overload Pressure | 321.08 inWC (11.6 psi; 80.0 kPa) |
Battery Type | 2 x AAA, NEDA 24A, IEC LR03 |
Battery Life | 150 hours typical alkaline. LED slow-blinks red when battery replacement is needed. |
Auto Power Off: | 2 hours (APO can be disabled) |
Wireless Range | 1000 feet (305 meters) line of sight. Obstructions affect distance. |
Radio Frequency | 2.4 GHz |
Operating Environment | -10°F to 122°F (-23°C to 50°C) at <75% RH |
Storage Temperature | -10°F to 140°F (-23°C to 60°C) at <80% RH (with batteries removed) |
Temperature Coefficient | 0.1 x (specified accuracy) per 1.8°F (-10°F to 64°F, 82°F to 122°F), per 1°C (-23°C to 18°C, 28°C to 50°C) |
Weight | 0.30 lbs (137 g) |
Fieldpiece Wireless Probe Vacuum Gauge with LCD Display - MG44
The NEW MG44 Micron Gauge Impact and Weather Resistant designed for the field
WHAT'S INCLUDED
SPECIFICATIONS
Minimum Device Requirement | BLE 4.0 devices running: iOS® 7.0 or Android™ 5.0 (Latest compatibility at www.fieldpiece.com) |
Connector type | 1/4” SAE male fitting |
Accuracy | ±(5% of reading + 5 microns) at 77°F (25°C), 50 to 1000 microns |
Range and Units | 50 to 25000 microns of mercury (English), 6 to 3333 Pascals (Metric), 0.06 to 33.33 mBar (Metric), 50 to 25000 mTorr (Metric), 0.05 to 25 Torr (Metric, equivalent to mmHg) |
Best Resolution | 1 micron of mercury (below 2000 microns), 1 Pascal (below 250 Pascals), 0.001 mBar (below 2.5 mBar), 1 mTorr (below 2000 mTorr), 0.001 Torr (below 2.5 Torr, equivalent to mmHg) |
Battery Type | 2 x AA Alkaline, NEDA 15A, JIS UM3, IEC LR6 |
Battery Life | 40 hours typical alkaline |
Auto Power Off | 15 minutes default (APO adjustable) |
Wireless Range | 1000 feet (305 meters) line of sight. Obstructions affect distance. |
Radio Frequency | 2.4 GHz |
Water Resistence | IP55 |
Operating Environment | 14°F to 122°F (-10°C to 50°C) at <75% RH |
Storage Temperature | -4°F to 140°F (-20°C to 60°C) at <80% RH (with batteries removed) |
Weight | 0.66 lbs (300 g) |
Fieldpiece Wireless Electronic Refrigerant Scale 114KG - SR47
The New Heavyweight Champion
WHAT'S INCLUDED
Please Note: Gas bottle in the image not included, for demonstration purposes only.
SPECIFICATIONS
Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative humidity | |
Over range | “OL” is displayed |
Maximum load | 252 lbs (114 kg) |
Max tank base diameter | 13 inches (33 cm) |
Auto power off | 30 minutes of inactivity (no change in weight or buttons pressed), (APO can be disabled) |
Backlight | Blue, turns off in 2 minutes if no buttons are pressed |
Accuracy | ±0.03%rdg + 0.25 oz (10 g), 0 to 66 lbs (0 to 30 kg) ±0.05%rdg + 0.25 oz (10 g), 66 to 252 lbs (30 to 114 kg) |
Resolution and Units | lb oz (0.25 oz), lb (0.1 lb), oz (0.3 oz), kg g (10 g), kg (0.1 kg), g (10 g) |
Temperature coefficient | 0.1 x (specified accuracy) per °F |
Wireless Range | 1000 feet (305 meters) line of sight |
Radio Frequency | 2.4 GHz |
Battery Type | Remote Display: 1 x 9V, NEDA 1604, JIS 006P, IEC 6F22 Platform: 6 x AA, NEDA 15A, JIS UM3, IEC LR6 |
Battery Life |
Remote Display: 80 hours typical alkaline (backlight off) Platform: 200 hours typical alkaline |
Remote Display | 80 hours typical alkaline (without backlight) |
Platform | 200 hours typical alkaline |
Operating environment | 32°F to 122°F (0°C to 50°C) at <75% RH |
Storage temperature | -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed) |
Water resistant | IP54 (Platform), IP64 (Remote) |
Weight | Platform with battery ~7 lbs (3190 g) Remote with battery 0.49 lbs (220 g) |
Fieldpiece True RMS AC/DC Wireless Power Clamp Meter - SC680INT
Built for HVAC-R - Packed with ideal measurements perfect for mini-splits!
Whether you’re working on small circuitry in mini-splits or on large commercial units, the new SC680 is packed with everything you need to install, service or troubleshoot any HVAC-R system.
WHAT'S INCLUDED
SPECIFICATIONS
Measure | up to 600 Amps AC & DC |
Display | 10000 count dual display |
Backlight | 5 minute duration with auto-off, blue color |
Overrange | “OL” or “-OL” is displayed |
Measurement rate | 3.3 times per second, nominal Zero: Automatic |
Operating environment | 32°F to 122°F (0°C to 50°C) at <70%RH |
Storage temperature | -4°F to 140°F (-20°C to 60°C), 0 to 80%RH (with battery removed) |
Accuracy | Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH |
Temperature coefficient | 0.1 x (specified accuracy) per °C [0°C to 19°C (32°F to 66°F), 28°C to 50° C (82°F to 122°F)] |
APO (Auto Power Off) | Approx. 30 minutes |
Power | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery life | 100 hours typical alkaline (No wireless, no backlight) |
Low battery indication | Battery icon blinks and "batt" is displayed when the battery voltage drops below the operating level |
Dimensions | 247mm(H) x 79mm(W) x 48mm(D) |
Weight | Approx. 345g including battery |
Altitude | Up to 6562 ft (2000m) |
Overload protection | 1000VDC or 750VAC rms unless otherwise stated |
Test leads | Use UL listed test leads that comply to UL61010-031 rated CATIV 600V, CATIII 1000V or above. Included test leads are gold-plated and have removable safety caps. |
Please operate the instrument following all instructions of the operator's manual to avoid impairing the safety of the product.
1 Year from Date of Purchase (excludes Consumables such as Filters, Gaskets, Leads, Batteries, Fuses, Sensors, Case etc)
Buy with 100% confidence knowing your purchase is backed by the full Manufacturer's Warranty. Please register your product with provided warranty card.
Australia-wide Flat Rate shipping of $15.00 per order.
This includes multiple products up to 5kg only.
Additional cost applies for orders over 5kg. Contact us for quotation.